{"id":13927,"date":"2025-05-22T10:32:56","date_gmt":"2025-05-22T08:32:56","guid":{"rendered":"https:\/\/www.convegnonazionaleaiic.it\/valutazione-hta-di-una-tecnologia-photon-counting-ct-il-caso-della-gestione-dei-cardiovascular-diseases-cvd\/"},"modified":"2025-06-04T14:24:17","modified_gmt":"2025-06-04T12:24:17","slug":"valutazione-hta-di-una-tecnologia-photon-counting-ct-il-caso-della-gestione-dei-cardiovascular-diseases-cvd","status":"publish","type":"post","link":"https:\/\/www.convegnonazionaleaiic.it\/valutazione-hta-di-una-tecnologia-photon-counting-ct-il-caso-della-gestione-dei-cardiovascular-diseases-cvd\/","title":{"rendered":"VALUTAZIONE HTA DI UNA TECNOLOGIA PHOTON-COUNTING CT: IL CASO DELLA GESTIONE DEI CARDIOVASCULAR DISEASES (CVD)"},"content":{"rendered":"<div class=\"row rigaaiic\">\n<div class=\"col-md-4 colaiic-4\">\n<p><img decoding=\"async\" class=\"imgaiic-1\" src=\"https:\/\/sem2000.s3.eu-west-1.amazonaws.com\/OLC\/0989478442373166690049893\/scent\/130762___wbJj9TFT.jpg\" alt=\"\" \/><img decoding=\"async\" class=\"imgaiic-2\" src=\"https:\/\/sem2000.s3.eu-west-1.amazonaws.com\/OLC\/0989478442373166690049893\/scent\/130762_logoAff__BaUUDzYU.jpg\" alt=\"\" \/><\/p>\n<p><strong><span class=\"titaffaiic-1\">AFFILIAZIONE<\/span><\/strong><\/p>\n<p class=\"affaiic-1\">asst sette laghi<\/p>\n<p><strong><br \/>\n<span class=\"titautaiic\">AUTORE PRINCIPALE<\/span><\/strong><\/p>\n<p class=\"autaiic\">ING. GIGLI SIMONE<\/p>\n<p><strong><span class=\"titrating\">VALUTA IL CHALLENGE<br \/>\n<\/span><\/strong><\/p>\n<div class=\"regaiic\"><em>Registrazione obbligatoria. Una valutazione consentita<\/em><\/div>\n<div class=\"register\">\t\t<div data-elementor-type=\"container\" data-elementor-id=\"14493\" class=\"elementor elementor-14493\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2912df93 e-con-full e-flex e-con e-child\" data-id=\"2912df93\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-2a881fc8 e-con-full guest-only e-flex e-con e-child\" data-id=\"2a881fc8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c324b4 elementor-widget elementor-widget-button\" data-id=\"9c324b4\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#login\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Login<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-110adcd1 elementor-widget elementor-widget-button\" data-id=\"110adcd1\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#register\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Registrazione<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-69a84aa e-con-full user-only e-flex e-con e-child\" data-id=\"69a84aa\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7aaa1461 elementor-widget elementor-widget-text-editor\" data-id=\"7aaa1461\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>login avvenuto<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20cd3cae elementor-widget elementor-widget-button\" data-id=\"20cd3cae\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.convegnonazionaleaiic.it\/wp-login.php?action=logout&#038;redirect_to=\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Logout<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<\/div>\n<div class=\"rating\">[ratingwidget]<\/div>\n<\/div>\n<div class=\"col-md-8 colaiic-8\" style=\"border-left: 1px solid; border-color: #005c97;\">\n<p><a name=\"top\"><\/a><\/p>\n<p><strong><span class=\"titgruppo\">GRUPPO DI LAVORO<\/span><\/strong><\/p>\n<div class=\"gruppo\"><strong>ING. GIGLI SIMONE<\/strong> asst sette laghi<\/p><\/div>\n<p><strong><span class=\"titarea\">AREA TEMATICA<\/span><\/strong><\/p>\n<div class=\"area\">Esperienze e metodologie di valutazione delle tecnologie<\/div>\n<p><strong><span class=\"titabstractaiic\">ABSTRACT<\/span><\/strong><\/p>\n<div class=\"abstractaiic\">La tecnologia TC Photon-Counting (PCD-CT) \u00e8 una rivoluzione in ambito radiologico. Ad oggi in letteratura non emergono molti studi di analisi multidisciplinare. Si \u00e8 cos\u00ec deciso di procedere con un Rapid Report HTA, in base al Core Model di EUnetHTA incentrato nella gestione dei cardiovascular diseanses (CVD). Ad oggi, la CVD in Italia \u00e8 una tra le patologie pi\u00f9 rischiose. Il gold standard riconosciuto dalle Linee Guida ESC 2024 \u00e8 la coronarografia (ICA), ma emerge sempre pi\u00f9 la necessit\u00e0 di sostituire la ICA nel ruolo di diagnosi e non di trattamento, con una procedura non invasiva, abbattere il sovra-utilizzo. I vantaggi tecnici sono, riduzione del rumore elettronico, ridotta risoluzione spaziale (0,11 mm in UHR), risoluzione temporale pari a 66 ms, spectral imaging, riduzione degli artefatti da movimento, di blooming e beam-hardening. Gli svantaggi sono nell\u2019ampio spazio di archiviazione PACS e nei costi elevati di adeguamento impiantistico, nonch\u00e9 nell\u2019elevato investimento sulla formazione. In termini di sicurezza del paziente, gli studi clinici suggeriscono una riduzione della dose del 43-50% con mantenimento della qualit\u00e0 dell&#8217;immagine, soprattutto nei pazienti obesi. Inoltre, si dimostra una riduzione del 20%-25% del volume di mdc iodato, nonch\u00e9 la possibilit\u00e0 di alternativi mdc non iodati. Altres\u00ec, un abbattimento dei rischi correlati alla procedura mininvasiva e una riduzione del rischio radiologico per l\u2019operatore. In termini di efficacia clinica, si evidenzia il miglioramento nella caratterizzazione delle placche arterosclerotiche, con stimato il 30% delle ICA evitabili grazie alla PCD-CT. Il costo di ammortamento secondo un\u2019analisi di clinical costing \u00e8 molto elevato rispetto la TC 64 slices single source. Si deve per\u00f2 tenere conto di numerosi introiti, quali, esami svolti, risparmi sul mdc e per la cessazione di procedure ICA non necessarie (minor gestione del paziente, dispositivi non pi\u00f9 necessari, equipe clinica non necessaria, abbattimento dei tempi dell\u2019esame), nonch\u00e9 aumento del numero di esami per maggiore velocit\u00e0 di acquisizione. Si conclude che, la PCD-CT \u00e8 una tecnologia innovativa la cui introduzione in una realt\u00e0 ospedaliera deve essere svolta con coscienza e con prospettiva di cambiamento nelle procedure sanitarie nonch\u00e9 cliniche tenendo ben presente i costi e ricavi in riferimento alla propria realt\u00e0 ed al grosso investimento tecnologico sostenuto, in un\u2019ottica di sostenibilit\u00e0 aziendale.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"flip\"><div style=\"display:block\">\n<!-- FlowPaper PDF flipbook plugin v.2.0.6 wordpress.org\/plugins\/flowpaper\/ -->\n<iframe title=\"FlowPaper flipbook pdf viewer\" width=\"100%\" height=\"500\" scrolling=\"no\" class=\"flowpaper-class\" frameborder=\"0\" allowFullScreen=\"true\" lightbox=\"false\" cover id src = \"https:\/\/flowpaper.com\/flipbook\/?pdf=https:\/\/sem2000.s3.eu-west-1.amazonaws.com\/OLC\/0989478442373166690049893\/scent\/130762___r0si9acn.pdf&title=&header=&theme=&singlepage=&thumbs=1&modified=250604224\" seamless=\"seamless\" style=\"margin-bottom:0;display:block;\">Your browser does not seem to support iframes. <a href=\"https:\/\/flowpaper.com\/flipbook\/?pdf=https:\/\/sem2000.s3.eu-west-1.amazonaws.com\/OLC\/0989478442373166690049893\/scent\/130762___r0si9acn.pdf\" target=\"_blank\">Click here to read this PDF<\/a>.<\/iframe>\n<div id=\"flowpaper-logo-bottom\" class=\"flowpaper-logo-bg\" style=\"background:linear-gradient(to right, rgba(0,0,0,0.65) 0%,rgba(0,0,0,0) 200px);width:100%;height:19px; padding-bottom: 1px; padding-left: 5px; padding-right: 10px; display: flex; align-items: center;z-index:9999\"><span style=\"height: 37px; padding-left: 6px;width:90%\"> <a id=\"flowpaper-link\" style=\"fill: #fff\" alt=\"FlowPaper logotype\" title=\"FlowPaper logotype\" href=\"https:\/\/flowpaper.com\" target=\"_blank\"> <img decoding=\"async\" alt=\"Publish PDF flipbooks online\" style=\"height:17px;width:auto;margin-top:11px;\" src=\"https:\/\/www.convegnonazionaleaiic.it\/wp-content\/plugins\/flowpaper-lite-pdf-flipbook\/assets\/flowpaper-logo.png\" border=\"0\"> <\/a> <\/span><span style=\" float: right; right: 0; font-size: 10px; white-space: nowrap; opacity:0.8\"><a href=\"https:\/\/flowpaper.com\/flipbook-maker\/\" target=\"_new\" style=\"text-decoration:none;border-bottom:none;\">Created using FlowPaper Flipbook Maker &#8599;<\/a><\/span><\/div><\/div>\r\n                <script>\r\n                document.addEventListener(\"DOMContentLoaded\", function(){\r\n                    var target_element, iframe_element;\r\n                    iframe_element = document.querySelector(\"iframe.flowpaper-class\");\r\n                    target_element = document.querySelector(\"\");\r\n                    iframe_element.style.height = target_element.offsetHeight + \"px\";\r\n                });\r\n                <\/script>\r\n            <\/div>\n<p><strong><span style=\"color: #003366;\"><a class=\"topaiic\" style=\"color: #003366; text-decoration: underline;\" href=\"#top\">Torna su \u00bb<\/a><\/span><br \/>\n<\/strong><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>La tecnologia TC Photon-Counting (PCD-CT) \u00e8 una rivoluzione in ambito radiologico. Ad oggi in letteratura non emergono molti studi di analisi multidisciplinare. Si \u00e8 cos\u00ec deciso di procedere con un Rapid Report HTA, in base al Core Model di EUnetHTA incentrato nella gestione dei cardiovascular diseanses (CVD). Ad oggi, la CVD in Italia \u00e8 una tra le patologie pi\u00f9 rischiose. Il gold standard riconosciuto dalle Linee Guida ESC 2024 \u00e8 la coronarografia (ICA), ma emerge sempre pi\u00f9 la necessit\u00e0 di sostituire la ICA nel ruolo di diagnosi e non di trattamento, con una procedura non invasiva, abbattere il sovra-utilizzo. I vantaggi tecnici sono, riduzione del rumore elettronico, ridotta risoluzione spaziale (0,11 mm in UHR), risoluzione temporale pari a 66 ms, spectral imaging, riduzione degli artefatti da movimento, di blooming e beam-hardening. Gli svantaggi sono nell\u2019ampio spazio di archiviazione PACS e nei costi elevati di adeguamento impiantistico, nonch\u00e9 nell\u2019elevato investimento sulla formazione. In termini di sicurezza del paziente, gli studi clinici suggeriscono una riduzione della dose del 43-50% con mantenimento della qualit\u00e0 dell&#8217;immagine, soprattutto nei pazienti obesi. Inoltre, si dimostra una riduzione del 20%-25% del volume di mdc iodato, nonch\u00e9 la possibilit\u00e0 di alternativi mdc non iodati. Altres\u00ec, un abbattimento dei rischi correlati alla procedura mininvasiva e una riduzione del rischio radiologico per l\u2019operatore. In termini di efficacia clinica, si evidenzia il miglioramento nella caratterizzazione delle placche arterosclerotiche, con stimato il 30% delle ICA evitabili grazie alla PCD-CT. Il costo di ammortamento secondo un\u2019analisi di clinical costing \u00e8 molto elevato rispetto la TC 64 slices single source. Si deve per\u00f2 tenere conto di numerosi introiti, quali, esami svolti, risparmi sul mdc e per la cessazione di procedure ICA non necessarie (minor gestione del paziente, dispositivi non pi\u00f9 necessari, equipe clinica non necessaria, abbattimento dei tempi dell\u2019esame), nonch\u00e9 aumento del numero di esami per maggiore velocit\u00e0 di acquisizione. Si conclude che, la PCD-CT \u00e8 una tecnologia innovativa la cui introduzione in una realt\u00e0 ospedaliera deve essere svolta con coscienza e con prospettiva di cambiamento nelle procedure sanitarie nonch\u00e9 cliniche tenendo ben presente i costi e ricavi in riferimento alla propria realt\u00e0 ed al grosso investimento tecnologico sostenuto, in un\u2019ottica di sostenibilit\u00e0 aziendale.<\/p>\n","protected":false},"author":8,"featured_media":14697,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[99],"tags":[],"class_list":["post-13927","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-esperienze-e-metodologie-di-valutazione-delle-tecnologie"],"_links":{"self":[{"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/posts\/13927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/comments?post=13927"}],"version-history":[{"count":0,"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/posts\/13927\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/media\/14697"}],"wp:attachment":[{"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/media?parent=13927"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/categories?post=13927"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.convegnonazionaleaiic.it\/wp-json\/wp\/v2\/tags?post=13927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}